ALTEC AP SERIES (2013–2025) — ELECTRICAL SYSTEM:WIRING:SWITCHES/KNOBS/BUTTONS
Altec Industries, Inc. (Altec) is recalling certain 2013-2025 AP45A trucks. The boom stow switch wire in the cargo storage area may become damaged, which can result in a short circuit, causing the wire to overheat.
ALTEC SERVICE BODY (2022–2026) — ELECTRICAL SYSTEM:PROPULSION SYSTEM:INVERTER
Altec Industries, Inc. (Altec) is recalling certain 2022-2026 Service Body vehicles. The inverter output AC wiring may be routed too tightly in the electrical receptacle enclosure and become damaged, possibly resulting in a short circuit.
ALTEC DIGGER DERRICK (2023–2025) — EQUIPMENT:MECHANICAL:CARRIER/RACK
Altec Industries, Inc. (Altec) is recalling certain 2023-2025 Digger Derrick vehicles. The vertical center of gravity with poles in the pole rack was not calculated properly, resulting in an incorrect pole rack capacity rating.
ALTEC AT SERIES (2014–2026) — POWER TRAIN:AUTOMATIC TRANSMISSION:PARK/NEUTRAL START INTERLOCK SWITCH
Altec industries, Inc. is recalling certain 2014-2026 AT Series Aerial Device vehicles. The transmission park interlock may be missing, allowing the aerial device to operate while the chassis is not in park.
ALTEC AC SERIES CRANE (2024–2026) — EQUIPMENT:MECHANICAL:BOOM/CRANE/LADDER:CRITICAL FASTENERS
Altec Industries (Altec) is recalling certain 2024-2026 AC Series Crane vehicles. The inside joints between the side plates and the base plates of the 26-foot insulating personnel jib (IJ26) may be missing welds.
ALTEC AA SERIES AERIAL DEVICE (2020–2026) — EQUIPMENT:MECHANICAL:BOOM/CRANE/LADDER:CONTROLS/CONTROL WIRING
Altec Industries, Inc. (Altec) is recalling certain 2022-2025 AT Series, 2021-2025 AN Series Aerial Device, 2020-2026 TA Series Aerial Device, 2021 L Series Aerial Device, 2021 LR Series Aerial Device, 2023-2025 AM Series Aerial Device, and 2024-2025 AA Series Aerial Device vehicles. The ground level emergency stop (E-stop) may not stop hydraulic functions of the machine when the machine is in ePTO mode.